Connection And Control Elements; Motor Monitoring X1C (Temperature, Brake); Control Terminal Strip X2A; Table 2 Overview Connection And Control Elements - KEB COMBIVERT F6 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT F6:
Table of Contents

Advertisement

3 | Product description
14

3.5 Connection and control elements

X1C
X3A
X3B
X2C
X2B
X4B
X2A
X4C
Table 2: Overview Connection and control elements

3.6 Motor monitoring X1C (temperature, brake)

Terminal strip X1C is a 6-pole, pluggable terminal strip with spring-cage connec-
tion. It contains:
– 1 output for control of 24V motor brakes
– 1 analog input for temperature detection

3.7 Control terminal strip X2A

Control terminal strip X2A is a 24-pole pluggable, double-row terminal strip with
spring-cage connection. It contains:
– 8 digital inputs
– 2 digital outputs
– 1 Relay output
– 24V outputs to supply the inputs
X1C
Temperature monitoring,
brake control
X2A
Control terminal strip for digital
inputs/outputs; 24V outputs; re-
lay output
X2B
Safety functions;
24V supply,
2 digital outputs
FS ST
X2C
CAN bus; analog inputs and out-
puts
X3A
Encoder interface channel A
X3B
Encoder interface channel B
VCC
X4A
Diagnostic interface with
NET ST
RS232/485 interface according
DEV ST
to DIN 66019II protocol; operator
OPT
slot
X4B
Fieldbus input / Port 0
X4A
X4C
Fieldbus output / Port 1
FS ST
LED Safety state
VCC
LED voltage supply (24V)
X2Z
NET ST LED network / fieldbus status
DEV ST LED Inverter / device status
OPT
optional
ma_dr_f6-cu-k-inst-20144795_en

Advertisement

Table of Contents
loading

Table of Contents