KEB COMBIVERT F5 Reference Manual page 175

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

LS40
Acceleration
Emergency
LS41
Start Jerk Emergency
LS42
Acceleration Jerk
Emergency
i
LS43
Deceleration
Emergency
LS44
Deceleration Jerk
Emergency
LS45
Stop Jerk Emergency
LS47
Intermediate Speed 3
Correction
LS - Speed Profile Parameters
Emergency (Intermediate Speed 3) Profile Rate Settings
Acceleration rate for Emergency Profile (Intermediate Speed 3 or Emergency
Profile input).
Start Jerk rate into acceleration for Emergency Profile (Intermediate Speed 3
or Emergency Profile input).
Acceleration Jerk rate into speed for Emergency Profile (Intermediate Speed
3 or Emergency Profile input).
All speeds will use the LS43-45 deceleration and jerk settings for the
Final Stop portion of the profile. Additionally, for analog and serial speed
control modes, if the direction is dropped before zero speed has been
reached, these rates will be used for the final deceleration.
Deceleration rate for Emergency Profile (Intermediate Speed 3 or Emergency
Profile input).
Jerk rate out of speed into deceleration for Emergency Profile (Intermediate
Speed 3 or Emergency Profile input).
Jerk rate out of deceleration into leveling speed and from leveling speed to
zero speed for Emergency Profile (Intermediate Speed 3 or Emergency Profile
input). Also, final jerk rate from leveling to zero speed for all runs.
The amount of leveling distance to be eliminated from run at Intermediate
Speed 3. Refer to parameter LS27 for further description.
Deceleration rate for Emergency Slowdown input function.