LI03 = D(Level - High - Inspect. - Interm.) [Leveling at start], NUM = 4
US04
Digital Speed
S
S
S
S
S
S
* Valid only at start (once leveling speed is reached it is not possible
to accelerate up to high speed again until after zero speed has been
selected)
LI03 = D(Inspect. - Level - High - Interm.), NUM = 8
US04
Digital Speed
S
S
S
S
S
LI03 = D(Level - Int.2 - High - Inspect), NUM = 12
US04
Digital Speed
S
S
S
S
S
S
Symbol:
LI - Input Parameters
Param.
Selection
-
Z
ERO
LS01
L
EVELING
*
LS02
H
S
IGH
PEED
LS02
H
S
IGH
PEED
LS03
I
NSPECTION
LS05
I
1
NTERMEDIATE
Param.
Selection
-
Z
ERO
LS01
L
EVELING
LS02
H
S
IGH
PEED
LS03
I
NSPECTION
LS05
I
1
NTERMEDIATE
Param.
Selection
-
Z
ERO
LS01
L
EVELING
LS02
H
S
IGH
PEED
LS03
I
NSPECTION
LS05
I
1
NTERMEDIATE
LS06
I
2
NTERMEDIATE
1
=
0
=
x
=
Control Inputs
I1
I2
0
0
1
0
1
1
0
1
0
0
0
0
Control Inputs
I1
I2
0
0
0
1
0
0
1
x
0
0
Control Inputs
I1
I2
0
0
1
0
0
0
0
0
1
1
0
1
Input is active
Input is not active
Setting has no effect or doesn't care
I3
I4
0
0
x
x
x
x
x
x
1
x
0
1
I3
I4
0
0
x
x
1
x
x
x
0
1
I3
I4
0
0
x
x
1
x
0
1
0
x
x
x