Error/Message Alt. /
(NUM)
Error Overload
EOL
(16)
*Additional information at end of section
Diagnostics and Troubleshooting
Description
Cause/Solution/Troubleshoot
Time dependent
Cause of excessive motor overload may include:
overload (See
overload curves
under Technical
Data, Section
2.9).
Error cannot be
reset until display
shows E.nOL!
Excessive current.
Verify correct motor data.
Verify correct encoder settings including:
LE02 Encoder Pulse Number
LE03 Swap Encoder Channels (A/B setting)
LE06 Encoder Pole position for PM Synchronous
Motors.
High mechanical load/issues (friction).