Testing the IGBTs, output circuit measurement
Positive Side
Negative lead of meter to positive DC terminal.
Positive lead of meter to U/V/W terminals.
-
Multimeter
Negative Side
Positive lead of meter to negative DC terminal.
Negative lead of meter to U/V/W terminals.
Multimeter
Testing the braking circuit
Positive Side
Negative lead of meter to positive DC terminal.
Positive lead of meter to PB terminal.
-
Multimeter
Negative Side
Positive lead of meter to negative DC terminal.
Negative lead of meter to PB terminal.
+ + +
+
-
-
+
+
-
Multimeter
Transistor Tests
Measurement
+ Terminal
+ Terminal
+ Terminal
Measurement
+ Terminal
+ Terminal
+ Terminal
-
Measurement
+ Terminal
Measurement
+ Terminal
Measurement
+ Terminal
Measurement
+ Terminal
E, G, and H Housings
To
Value
Measurement
U
0.3 - 0.4
- Terminal
V
0.3 - 0.4
- Terminal
W
0.3 - 0.4
- Terminal
R, U, and W Housings
To
Value
Measurement
U
0.2 - 0.4
- Terminal
V
0.2 - 0.4
- Terminal
W
0.2 - 0.4
- Terminal
E Housing
To
Value
Measurement
PB
0.4
- Terminal
G Housing
To
Value
Measurement
PB
0.4
- Terminal
H Housing
To
Value
Measurement
PB
0.3
- Terminal
R, U, and W Housings
To
Value
Measurement
PB
0.3
- Terminal
To
Value
U
0.3 - 0.4
V
0.3 - 0.4
W
0.3 - 0.4
To
Value
U
0.2 - 0.4
V
0.2 - 0.4
W
0.2 - 0.4
To
Value
PB
Open
To
Value
PB
1.5
To
Value
PB
0.3
To
Value
PB
0.3