KEB COMBIVERT F5 Reference Manual page 122

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

LI - Input Parameters
122
Digital Speed Selection
Utilizes four inputs to select up to five different speeds.
Older KEB elevator software and worldwide variants are available. Because of
this, several different truth tables for the Digital Speed Selection are available:
Version:
LI03 Setting:
US Lift
D(Level - Correct. - High - Inspect.)
KEB (DE)
D(Level - High - Inspect. - Interm.) [Level at Start]
SFKEB
D(Inspect. - Level - High - Interm.)
-
D(Level - Int.2 - High - Inspect.)
The following are the corresponding logic tables. Although inputs I1...I4 are
shown, the inputs actually used for speed selection are configurable and
can be defined in LI04-11. Refer to Section 3.1.1 or 3.2.2 for input terminal
assignments.
LI03 = D(Level - Correct. - High - Inspect), NUM = 0
US04
Digital Speed
Selection
S
Z
ERO
S
L
EVELING
S
H
S
IGH
PEED
S
I
NSPECTION
S
C
ORRECTION
S
I
1
NTERMEDIATE
Symbol:
1
0
x
Param.
I1
-
0
LS01
1
LS02
0
LS03
0
LS04
0
LS05
1
=
Input is active
=
Input is not active
=
Setting has no effect or doesn't care
NUM
Control Inputs
I2
I3
0
0
0
x
0
1
0
0
1
x
1
0
0
4
8
12
I4
0
x
x
1
x
x

Hide quick links: