CH - Configuration Handling
220
CH10 - 15: LED Diagnostics
The LEDs on the serial operator are used to indicate operational status. In
addition they can be used for troubleshooting or diagnostics.
For each LED, a parameter will select whether the LED has its normal function
or is mapped to a special function. The tables below describe the function.
CH10 and CH13:
Value: Function:
0
Default Normal Function The standard function
1
Input Status
2
Output Status
3
Output Condition Status Bit 0-7 of Dg16
4
Lift App Control Word
5
Inverter Control Word
6
Field Bus Control Word Bit 0-15 of Fb01
7
CAN Bus Control Word Bit 0-15 of Fb43
8
Raw Memory Address
CH11, 12 and CH14, 15:
Para:
Value:
Function:
CH11
000000h -
Memory Address
CH14
FFFFFFh
CH12
0h -
Data Size and Bit 00h-07h = bits 0-7 byte sized data
CH15
7h
Description:
Bit 0-7 = I1 - I8 in Dg01
Bit 0-3 of Dg11
Bit 0-31
Bit 0-15 of Sy50 (internal)
Bit 0-31 of the address and bit in CH12
and CH13
Description:
The memory address of the function
selected in CH.10 and CH.13.
This parameter auto populates
once CH.10 and CH.13 have been
defined and will not need further
adjustment.
10h-1Fh = bits 0-15 word sized data
20h-3Fh = bits 0-31 long sized data