KEB COMBIVERT F5 Reference Manual page 227

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

i
LA31
Analog Output 1
Function
i
LA33
Analog Output 1 Gain
LA34
Analog Output 1 X
Offset
LA35
Analog Output 1 Y
Offset
LA - Analog I/O Parameters
Analog Output 1
Settings LA31-35 for Analog Output 1 correspond with terminal ANOUT1.
The following options in the table below can be assigned to the analog output.
Speeds are scaled such that 10V = contract speed.
Setting:
Absolute actual speed
Absolute command speed
Actual speed
Command speed
Output voltage
DC bus voltage
Phase current
Actual Torque
Default (LA31) = Actual Speed (2)
Default (LA36) = Actual Torque (7)
Similar to the analog inputs, with parameters LA33-35 or LA38-40, the
corresponding analog output signals can be adapted in X and Y direction
as well as in the gain. The input values correspond to pre-processed
values internal to the drive and the output values would be the post-
processed analog output voltage from the drive output terminals.
The analog pattern can be scaled directly through this parameter. This
parameter is automatically scaled according to contract speed and machine
data.
Refer to parameter LA05 for further description.
This parameter shifts the input characteristic on the X-axis.
Refer to parameter LA06 for further description.
This parameter shifts the input characteristic on the Y-axis.
Refer to parameter LA07 for further description.
0...10V =
0...RPM at Contract Speed
0...RPM at Contract Speed
0...RPM at Contract Speed
0...RPM at Contract Speed
0...500V
0...1000V
0...2 x Rated Inverter Current
0...3 x Rated Motor Torque
NUM
0
1
2
3
4
5
6
7