KEB COMBIVERT F5 Reference Manual page 211

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

LX09
Watchdog Time
LX10
EdOH Function
LX11
Reference Splitting
LX12
Baud Rate
LX - Special Function Parameters
This parameter adjusts the serial watchdog timer between the keypad
and control card.
A setting of 0 or Off turns off the watchdog timer. This mode of operation
is recommended for trouble shooting purposes only.
This parameter can be used to activate the temperature sensor input (T1 and
T2) on the drive. With this input activated, if the resistance between T1 and
T2 becomes greater than 1650 ohms, the drive will trigger an 'Error Motor
Overheat' fault indicating that the temperature sensor is too hot.
Setting:
Description:
Off
No function
On
After the sensor triggers, the drive will fault after
modulation turns off at the end of the run or after
a 120 second time delay, whichever occurs first.
Default = Off (0)
This function creates a slope between two successive speed values which
are transferred serially. This parameter should be adjusted for a time double
the actual serial update rate of the speed command. The function smooths
out the relatively coarse steps which can occur during rapidly changing speed
commands.
This parameter sets the external serial communication baud rate at connector
X6D (typically used for connection with Combivis). This communication port
supports the DIN 66019 II standard.
Settings:
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
38400 bps
55500 bps
115200 bps
Default = 38400 bps (5)
NUM
0
1
NUM
0
1
2
3
4
5
6
7
211