System Timers
Description
The System Hold Recall Timer determines the time before a call placed on
System Hold recalls the station placing the hold. If unanswered by that
station, the call recalls the attendant.
By default, the System Hold Recall Timer is set for 60 seconds and is
variable from 000-300 seconds. An entry of 000 disables the timer and
there is no recall.
Exclusive Hold Recall Timer
Programming Steps
1. Press the EXCLUSIVE HOLD RECALL TIMER flex button (FLASH 01,
2. Enter a valid number on the dial pad that corresponds to
3. Press HOLD to save the entry. A confirmation tone is heard and the
Description
The System Hold Recall Timer determines the time before a call placed on
Exclusive Hold recalls the station placing the Hold. If unanswered by that
station, the call recalls the attendant.
By default, the Exclusive Hold Recall Timer is set for 180 seconds and is
variable from 000-300 seconds. An entry of 000 disables the timer and
there is no recall.
Button #2). The following message displays:
EXC HOL D R ECA LL
18 0
000-300 seconds.
display updates.
0 00- 30 0
2-5