Repeat Redial Timer; Attendant Display Timer - Vodavi STARPLUS Triad 1 System Programming Manual

Hide thumbs Also See for STARPLUS Triad 1:
Table of Contents

Advertisement

Additional System Timers

Repeat Redial Timer

Programming Steps
1. Press the RPT REDIAL TIMER flex button (FLASH 02, Button #1). The
2. Enter a valid number that corresponds to 006-999 seconds.
3. Press HOLD to save the entry. A confirmation tone is heard and the
Description
The Repeat Redial Timer lets a digital key station press a flexible button or
dial a code and redial a busy or no-answer number at specific intervals.
The user is signaled via a queue callback indication.
The Redial flexible button flashes at the callback rate of 120 ipm for
15 seconds.
By default, the Repeat Redial Timer is set for 1 minute (60) and is variable
from 006-999 seconds.

Attendant Display Timer

Programming Steps
1. Press the ATTENDANT DISPLAY TIMER flex button (FLASH 02,
2. Enter a valid number on the dial pad that corresponds to
following message displays
R PT R ED IA L
06 0
display updates.
If station does not answer within 15 seconds, the callback is
cancelled.
If station is busy with an internal/external call when the Redial queue
callback occurs, the callback occurs after the user goes on-hook.
Button #2). The following message displays:
AT T EN D AN T D ISP LAY
01
00-99 seconds.
0 06- 99 9
0 0-9 9
2-19