Release Timer; Reseize Timer - Vodavi STARPLUS Triad 1 System Programming Manual

Hide thumbs Also See for STARPLUS Triad 1:
Table of Contents

Advertisement

Page C Introduction
Description
When Wink signaling is programmed, this timer determines how long the
Triad 1/2/3
DTMF digits are sent from the Central Office. This option allows the
installer a method to adjust the Wink Signal on a per CO Line basis. The
Wink Signal can be used on DID and T-1 E & M type trunks. By default, the
Wink Timer is set for 140 ms.

Release Timer

Programming Steps
1. Press the RELEASE TIMER Button (FLASH 40, Page C, Button #4) in
2. Enter a valid number on the dial pad which corresponds to
3. Press HOLD button to save entry. A confirmation tone is heard and
Description
The Release Timer option allows the user to adjust the release timer on a
per CO Line basis. The release timer is used on ground start type trunks.
This timer is a lead filter timer. The CO must remove ground from the tip
lead for longer than this timer in order for the system to recognize it. By
default, the Release Timer is set for 200 ms.

Reseize Timer

Programming Steps
1. Press the RESEIZE TIMER Button (FLASH 40, Page C, Button #5) in
System keeps the T-1 TIE Line circuit reversed before any
the flexible button field. The following message displays:
R ELEA SE TIM ER
02 0
000-255 ms.
the display updates.
the flexible button field. The following message displays:
R ESE IZE T IMER
20 0
0 00- 25 5
0 00- 25 5
3-33