3-36
Description
The Preset Forward Timer determines the time an outside line rings
before being forwarded to a predetermined destination. If a forward
destination is programmed in the CO line field, the CO calls forward to
that destination after the CO preset forward timer expires. This forward
occurs regardless of how many stations the line is ringing.
The digits entered for the CO line are sent in the station field.This feature
applies to initial CO ringing lines only and works with Preset Forward CO
Line assignments. By default, the CO Line Preset Forward Timer is set at
10 seconds and is variable from 00-99 seconds. A [00] entry disables the
timer and the feature is disabled.

DID Collect Timer

Programming Steps
1. Press the DID COLLECT TIMER Button (FLASH 40, Page C, Button #9)
2. Enter a valid number on the dial pad that corresponds to 010–200
3. Press HOLD button to save entry. A confirmation tone is heard and
Description
The DID Collect Timer is only used when the DID Incoming Signaling is
set for dial pulse. This is a time-out timer that looks at the incoming digits
one digit at a time. If a second digit isn't detected within the 150ms, the
telephone system attempts to process that digit. If a second digit is
detected, the system waits 150ms to see if a third digit is received.
Otherwise, the telephone system attempts to process the two digits
already received. This process continues until no additional digits are
received and the time-out timer expires. By default, the DID Collect Timer
is set for 150 milli-seconds and is variable from 100ms to 2.0 seconds.
in the flexible button field. The following message displays:
D ID COLL ECT TIME R
01 5
(100 ms to 2.0 seconds).
the display updates.