10 Output Assemblies (Converter Consumes)
Multi-Function Digital Output 1
Multi-Function Digital Output 2
Multi-Function Digital Output 3
D1000: Voltage Reference
R1000: -

(Vendor Specific Yaskawa Electric (YE) Assy) Extended Speed/Torque Control

Output - 115 (0x73)

Output Instance
Word
0
1
2
115
3
4 - 5
6
7
8
9 - 19
Name
D1000: Run
R1000: Auto Run
D1000: -
R1000: Forced Run
70
Terminal M1/M2 (varies by converter model)
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Terminals M3 and M4
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when H2-02 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Terminals M5 and M6
0: M5/M6 OFF
1: M5/M6 ON
This function is enabled only when H2-03 is set to F.
Note:
The names of the digital outputs are different for different converter series.
D1000: Voltage Reference
Sets converter voltage reference.
R1000: -
Byte
Bit 7
Bit 6
Multi-
Multi-
0
Function
Function
Input 8
Input 7
Multi-
Multi-
Function
Function
1
Digital
Digital
Output 3
Output 2
2
3
4
5
6
7
8 - 11
12
13
14
15
16
17
18 - 39
D1000: Run converter
0: Stop
1: Run
R1000: Run converter in auto
0: Stop
1: Auto Run
D1000: -
R1000: Force run converter
0: Stop
1: Force Run
Bit 5
Bit 4
Bit 3
Multi-
Multi-
Multi-
Function
Function
Function
Input 6
Input 5
Input 4
Multi-
Function
-
-
Digital
Output 1
D1000: Voltage Reference (Low Byte)
R1000: -
D1000: Voltage Reference (High Byte)
R1000: -
-
-
-
-
Reserved
Analog Output 1 (Low Byte)
Analog Output 1 (High Byte)
Analog Output 2 (Low Byte)
Analog Output 2 (High Byte)
Digital Outputs (Low Byte)
Digital Outputs (High Byte)
Reserved
Description
YASKAWA SIEP C730600 0DB EtherNet/IP Technical Manual
Bit 2
Bit 1
Bit 0
D1000: -
D1000: Run
Multi-
Function
R1000:
R1000: Auto
Input 3
Forced Run
Run
-
Fault Reset
External Fault