YASKAWA SI-EN3D Technical Manual page 35

Hide thumbs Also See for SI-EN3D:
Table of Contents

Advertisement

No.
Name
(Hex.)
F7-15
Communication Speed
Selection
(03F3)
F7-16
Timeout Value
(03F4)
F7-17
EtherNet/IP Speed Scaling
Factor
(03F5)
F7-18
EtherNet/IP Current Scale
Factor
(03F6)
F7-19
EtherNet/IP Torque Scale
Factor
(03F7)
F7-20
EtherNet/IP Power Scaling
Factor
(03F8)
F7-21
EtherNet/IP Voltage Scale
Factor
(03F9)
F7-22
EtherNet/IP Time Scaling
(03FA)
F7-23 - F7-27
Dynamic Output Assembly
Parameters 1 to 10
(03FB - 03FF)
F7-28 - F7-32
(0370 - 0374)
F7-33 - F7-42
Dynamic Input Assembly
Parameters 1 to 10
(0375 to 037E)
No.
U6-80 - U6-83
Option IP Address 1 - 4
U6-84 - U6-87
Online Subnet 1 - 4
U6-88 - U6-91
Online Gateway 1 - 4
U6-92
Online Speed
YASKAWA SIEP C730600 0DB EtherNet/IP Technical Manual
–When 8: Full/Auto, port 1 is set to Full and port 2 is set to Auto.
Sets the communications speed (Port 1/Port 2).
10 : 10/10 Mbps
100 : 100/100 Mbps
101 : 10/100 Mbps
102 : 100/10 Mbps
Note:
F7-15 is only effective when the port is set to half or full duplex in F7-14 [Duplex Mode
Selection].
Sets the detection time for a communications timeout.
Note:
• Set this parameter to 0.0 to disable the connection timeout function.
• This parameter is not available in all 1000-series drives.
• Changes to this parameter take effect immediately. It is not necessary to cycle power on the
drive.
Sets the scaling factor for the speed monitor in EtherNet/IP Class ID 2A (Hex.) Object.
Note:
Changes to this parameter take effect immediately. It is not necessary to cycle power on the
drive.
Sets the scaling factor for the output current monitor in EtherNet/IP Class ID 2A (Hex.) Object.
Note:
Changes to this parameter take effect immediately. It is not necessary to cycle power on the
drive.
Sets the scaling factor for the torque monitor in EtherNet/IP Class ID 2A (Hex.) Object.
Note:
Changes to this parameter take effect immediately. It is not necessary to cycle power on the
drive.
Sets the scaling factor for the power monitor in EtherNet/IP Class ID 2A (Hex.) Object.
Note:
Changes to this parameter take effect immediately. It is not necessary to cycle power on the
drive.
Sets the scaling factor for the voltage monitor in EtherNet/IP Class ID 2A (Hex.) Object.
Note:
Changes to this parameter take effect immediately. It is not necessary to cycle power on the
drive.
Sets the scaling factor for the time monitor in EtherNet/IP Class ID 2A (Hex.) Object.
Note:
Changes to this parameter take effect immediately. It is not necessary to cycle power on the
drive.
Parameters used in Output Assemblies 116, 117, 118, 119, 120. Each parameter contains a
MEMOBUS/Modbus address. The value received for the Output Assembly will be written to this
corresponding MEMOBUS/Modbus address. A MEMOBUS/Modbus address value of 0 means
that the value received for the Output Assembly will not be written to any MEMOBUS/Modbus
register.
Parameters used in Input Assemblies 166, 167, 168, 169, 170. Each parameter contains a
MEMOBUS/Modbus address. The value sent for the Input Assembly will be read from this
corresponding MEMOBUS/Modbus address. A MEMOBUS/Modbus address value of 0 means
that the value sent for the Input Assembly is not defined by the user, therefore the option default
register value will be returned.
Table 6.1 Option Monitor
Name
Shows the currently available local IP Address.
• U6-80: First octet
• U6-81: Second octet
• U6-82: Third octet
• U6-83: Forth octet
Shows the currently available subnet mask.
• U6-84: First octet
• U6-85: Second octet
• U6-86: Third octet
• U6-87: Forth octet
Shows the currently available gateway address.
• U6-88: First octet
• U6-89: Second octet
• U6-90: Third octet
• U6-91: Forth octet
Shows CN1 Port 1 link speed currently available.
Description
Description
6 Related Drive Parameters
Default
(Range)
10
(10 - 102)
0.0 s
(0.0 s - 30.0 s)
0
(-15 - 15)
0
(-15 - 15)
0
(-15 - 15)
0
(-15 - 15)
0
(-15 - 15)
0
(-15 - 15)
0
(-)
0
(-)
Range
0 - 255