5 Installation Procedure
3.
Remove the screw (B) installed in the drive grounding terminal (A).
A - Drive grounding terminal (FE)
4.
Use the screw (B) installed in the FE ground terminal of the drive (A) to connect one end of the included
ground wire (C) to the ground terminal on the drive.
Tighten the screw to a correct tightening torque:
• 0.5 N∙m to 0.6 N∙m (4.4 in∙lb to 5.3 in∙lb)
Note:
Route ground wire on the right side of the stud (D).
A - Drive grounding terminal (FE)
B - Ground screw
5.
Install the option (A) into the connector (C) (HV600: CN5, FP605: CN5-A) on the drive and use the
included screw (B) to put it in place.
Tighten the screw to a correct tightening torque:
• 0.5 N∙m to 0.6 N∙m (4.4 in∙lb to 5.3 in∙lb)
28
Figure 5.23 Remove the Screw from the Drive Grounding Terminal
Figure 5.24 Connect the Ground Wire
B - Ground screw
C - Ground wire
D - Stud