17 Option Installation

Status
Communications time-out (non-
fatal)
Duplicate IP Address
Default MAC Address
Two drive monitor parameters, U6-98 [First Fault] and U6-99 [Current Fault] assist the user in network
troubleshooting.
• U6-98 displays the first declared fault since the last power cycle. U6-98 is only cleared upon drive power-up.
• U6-99 displays the present option status. U6-99 is cleared upon a network-issued fault reset and upon power-up.
If another fault occurs while the original fault is still active, parameter U6-98 retains the original fault value and
U6-99 stores the new fault status value.

Option Compatibility

You can connect a maximum of 3 options at the same time depending on the type of option.
Note:
• You can only connect one option to the GA500 and HV600 drives. Connect the option to the CN5 connector.
• You can connect two options to an FP605 drive. Connect the communication option to the CN5-A connector.
• Compatible communication options are different for different models. Refer to the drive manuals for more information.
Option
*1
*1
PG-B3
, PG-X3
*1 *3 *4
*1 *3 *4
PG-RT3
, PG-F3
*5
*5
DO-A3
, AO-A3
SI-C3, SI-N3, SI-P3, SI-S3, SI-T3, SI-ET3,
SI-ES3, SI-B3, SI-M3,
*4
*4
*4
SI-W3
, SI-EM3
, SI-EM3D
EP3, JOHB-SMP3,
*5 *6
*5 *6
AI-A3
, DI-A3
*1
Not available for GA500, HV600, or FP605 drives.
*2
To connect two PG options, use the CN5-C and CN5-B connectors. To connect only one PG option, use the CN5-C connector.
*3
If you use the motor switching function, you cannot use this option.
*4
Not available for 1000-Series drive models with capacities between 450 and 630 kW (650 to 1000 HP).
*5
Not available for GA500 or HV600 drives.
*6
To use AI-A3 and DI-A3 input statuses as monitors, connect the options to CN5-A, CN5-B, or CN5-C.
17
Option Installation
Verify the following installation conditions to make sure that other devices and machinery used with this option
and drive also comply with EMC guidelines:
1.
Use dedicated shield cable for the option and external device (encoder, I/O device, master), or run the
wiring through a metal conduit.
120
Status
Fault Declared
Value (U6-
98/U6-99)
bUS
1101
bUS
1102
-
1103
Table 16.3 Option Compatibility
*4
*4
, SI-EN3
, SI-EN3D
, SI-
The node timer (Requested Packet Interval) timed out.
This node and at least one other node have the same IP Address.
Factory default MAC Address programmed into the option.
Note:
Return the option to Yaskawa or your nearest sales representative and request the setting
change.
Connector
CN5-B, C
CN5-C
CN5-A, B, and C
CN5-A
YASKAWA SIEP C730600 0DB EtherNet/IP Technical Manual
Description
Number of Options Possible
*2
2
1
1
1