8 Output Assemblies (Drive Consumes)
Name
External Fault
Fault Reset
Multi-Function Digital Output 1
Multi-Function Digital Output 2
Multi-Function Digital Output 3
Speed Reference
Dynamic Outputs
(Vendor Specific Yaskawa Electric (YE) Assy) 18 Byte Dynamic Output - 119
(0x77)
Output Instance
Word
0
1
119
2
3
4
5
6
7
8
Name
Run Fwd
Run Rev
Multi-Function Input 3
48
External Fault EF0
0: -
1: External Fault [EF0]
Fault Reset
0: -
1: Fault Reset
Terminal M1/M2 (varies by drive model)
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Terminal M3/M4 (varies by drive model)
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when H2-02 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Terminal M5/M6 (varies by drive model)
0: M5/M6 OFF
1: M5/M6 ON
This function is enabled only when H2-03 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Speed Command
Sets drive speed reference.
Unit is min
-1
or determined by o1-03.
Unit is not affected by Speed Scale SS.
Contains the data to be written to the MEMOBUS/Modbus address defined in the given parameter. A value of 0 in the given
parameter means it is not used, therefore the value received for this given parameter will not be written to any MEMOBUS/
Modbus register. If the PPA is Input Assembly 166, then any errors occurring during a write will be flagged. Refer to page
58
for more information.
Byte
Bit 7
Bit 6
Multi-
Multi-
0
Function
Function
Input 8
Input 7
Multi-
Multi-
Function
Function
1
Digital
Digital
Output 3
Output 2
2
3
4 - 5
6 - 7
8 - 9
10 - 11
12 - 13
14 - 15
16 - 17
Forward Run Command
0: Stop
1: Forward Run
Reverse Run Command
0: Stop
1: Reverse Run
Terminal S3 Function Input
Description
Bit 5
Bit 4
Bit 3
Multi-
Multi-
Multi-
Function
Function
Function
Input 6
Input 5
Input 4
Multi-
Function
-
-
Digital
Output 1
Speed Reference (Low Byte)
Speed Reference (High Byte)
Dynamic Output 1 [F7-23], Default: Not Used
Dynamic Output 2 [F7-24], Default: Not Used
Dynamic Output 3 [F7-25], Default: Not Used
Dynamic Output 4 [F7-26], Default: Not Used
Dynamic Output 5 [F7-27], Default: Not Used
Dynamic Output 6 [F7-28], Default: Not Used
Dynamic Output 7 [F7-29], Default: Not Used
Description
YASKAWA SIEP C730600 0DB EtherNet/IP Technical Manual
Bit 2
Bit 1
Bit 0
Multi-
Function
Run Rev
Run Fwd
Input 3
-
Fault Reset