(Vendor Specific Yaskawa Electric (Ye) Assy) 24-Byte Dynamic Input; (0Xaa) - YASKAWA SI-EN3D Technical Manual

Hide thumbs Also See for SI-EN3D:
Table of Contents

Advertisement

Name
LOCAL/REMOTE
Multi-Function Digital Output 1
Multi-Function Digital Output 2
Multi-Function Digital Output 3
Output Voltage
F7-33 Alarm Code
D1000: F7-34 Output Power
R1000: F7-34 Not Used
F7-35 Terminal A2 Input
F7-36 Terminal S1 - S12
F7-37 Terminal A3 Input
F7-38 Not Used
F7-39 NetRef (Status)
F7-39 NetCtrl
F7-39 Not Used

(Vendor Specific Yaskawa Electric (YE) Assy) 24-Byte Dynamic Input 10 - 170

(0xAA)

Input Instance
Word
0
1
170
2
3
4
5
YASKAWA SIEP C730600 0DB EtherNet/IP Technical Manual
0: -
1: Undervoltage
Run command is from network
0: Run command is not from network
1: Run command is from network
Terminal M1/M2 (varies by converter model)
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Terminal M3/M4 (varies by converter model)
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when H2-02 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Terminal M5/M6 (varies by converter model)
0: M5/M6 OFF
1: M5/M6 ON
This function is enabled only when H2-03 is set to F.
Note:
The names of the digital outputs are different for different converter series.
Converter Output Voltage
Programmable: MEMOBUS/Modbus (0x7F)
D1000: Programmable: MEMOBUS/Modbus (0x47)
Monitor parameter U1-08
R1000: -
Programmable: MEMOBUS/Modbus (0x4F)
Monitor parameter U1-14
Programmable: MEMOBUS/Modbus (0x49)
Monitor parameter U1-10
Programmable: MEMOBUS/Modbus (0x50)
-
Voltage command is from network
0: Voltage command is not from network
1: Voltage command is from network
Run command is from network
0: Run command is not from network
1: Run command is from network
-
Byte
Bit 7
Bit 6
0
Faulted
Alarm
1
-
-
2
3
4 -5
6 - 7
8 - 9
10 - 11
11 Input Assemblies (Converter Produces)
Description
Bit 5
Bit 4
Bit 3
During Run -
Ready
Operation
Reset
Ready
Multi-
Multi-
Multi-
Function
Function
Function
Digital
Digital
Digital
Output 3
Output 2
Output 1
Output Voltage (Low Byte)
Output Voltage (High Byte)
Parameter [F7-33], Default: Alarm Code
D1000: Parameter [F7-34], Default: Output Power
R1000: Parameter [F7-34], Default: Not Used
Parameter [F7-35], Default: Terminal A2 Input
Parameter [F7-36], Default: Terminal S1 - S8 Input
Bit 2
Bit 1
Bit 0
During
Regenerative
-
Running
Operation
LOCAL/
Uv
oPE
REMOTE
91