Epson S1C17624 Technical Manual page 328

Cmos 16-bit single chip microcontroller
Table of Contents

Advertisement

aPPenDiX a liST OF i/O ReGiSTeRS
Register name address
Bit
uaRT Ch.1
0x4124
D7
Control Register
(8 bits)
D6
(uaRT_CTl1)
D5
D4
D3–2 –
D1
D0
uaRT Ch.1
0x4125
D7
expansion
(8 bits)
D6–4 iRClK[2:0] IrDA receive detection clock
Register
(uaRT_eXP1)
D3–1 –
D0
0x4200–0x4208
Register name address
Bit
T8F Ch.0
0x4200
D15–4 –
Count Clock
(16 bits)
D3–0 DF[3:0]
Select Register
(T8F_ClK0)
T8F Ch.0
0x4202
D15–8 –
Reload Data
(16 bits)
D7–0 TR[7:0]
Register
(T8F_TR0)
T8F Ch.0
0x4204
D15–8 –
Counter Data
(16 bits)
D7–0 TC[7:0]
Register
(T8F_TC0)
T8F Ch.0
0x4206
D15–12 –
Control Register
(16 bits)
D11–8 TFMD[3:0]
(T8F_CTl0)
D7–5 –
D4
D3–2 –
D1
D0
T8F Ch.0
0x4208
D15–9 –
interrupt
(16 bits)
D8
Control Register
D7–1 –
(T8F_inT0)
D0
aP-a-6
name
Function
reserved
Reien
Receive error int. enable
Rien
Receive buffer full int. enable
Tien
Transmit buffer empty int. enable
reserved
RBFi
Receive buffer full int. condition setup 1 2 bytes
RXen
UART enable
reserved
division ratio select
reserved
iRMD
IrDA mode select
name
Function
reserved
Count clock division ratio select
reserved
Reload data
TR7 = MSB
TR0 = LSB
reserved
Counter data
TC7 = MSB
TC0 = LSB
reserved
Fine mode setup
reserved
TRMD
Count mode select
reserved
PReSeR
Timer reset
PRun
Timer run/stop control
reserved
T8Fie
T8F interrupt enable
reserved
T8FiF
T8F interrupt flag
Seiko epson Corporation
Setting
init. R/W
1 Enable
0 Disable
1 Enable
0 Disable
1 Enable
0 Disable
0 1 byte
1 Enable
0 Disable
IRCLK[2:0]
Division ratio
0x0 R/W Source clock = PCLK
0x7
1/128
0x6
1/64
0x5
1/32
0x4
1/16
0x3
1/8
0x2
1/4
0x1
1/2
0x0
1/1
1 On
0 Off
Fine Mode 8-bit Timer Ch.0
Setting
init. R/W
DF[3:0]
Division ratio
0x0 R/W Source clock = PCLK
0xf
reserved
0xe
1/16384
0xd
1/8192
0xc
1/4096
0xb
1/2048
0xa
1/1024
0x9
1/512
0x8
1/256
0x7
1/128
0x6
1/64
0x5
1/32
0x4
1/16
0x3
1/8
0x2
1/4
0x1
1/2
0x0
1/1
0x0 to 0xff
0x0 R/W
0x0 to 0xff
0xff
0x0 to 0xf
0x0 R/W Set a number of times
1 One shot
0 Repeat
1 Reset
0 Ignored
1 Run
0 Stop
1 Enable
0 Disable
1 Cause of
0 Cause of
interrupt
interrupt not
occurred
occurred
S1C17624/604/622/602/621 TeChniCal Manual
Remarks
0 when being read.
0
R/W
0
R/W
0
R/W
0 when being read.
0
R/W
0
R/W
0 when being read.
0 when being read.
0
R/W
Remarks
0 when being read.
0 when being read.
0 when being read.
R
0 when being read.
to insert delay into a
16-underflow period.
0 when being read.
0
R/W
0 when being read.
0
W
0
R/W
0 when being read.
0
R/W
0 when being read.
0
R/W Reset by writing 1.