Configure Network; Figure 158: Send Copy All Profiles; Figure 159: Configure Network - Jamesway Sentry Manual

Display panel
Table of Contents

Advertisement

This dialog box asks for
confirmation from the operator
before the profiles are copied.
Selecting 'Abort' or pressing
"EXIT" will abort this function
without copying the profiles.
Choose 'Copy Profiles' using
the arrow keys and press
"ENTER'' to transfer all of the
valid profiles. A profile which
was valid on the destination
machine, but is unused on the
source machine, will remain
unchanged.
NOTE: If any of the machines
receiving the new profile are
currently using a profile from
an affected slot, they will automatically adjust the setpoints to reflect the new profile.

5.6 Configure Network

This function is used to
initialize a network, so that
each display panel knows what
units are connected to the
network. This operation can
only be executed from the
Master Display panel. Once
this function is invoked, the
master display will send out
every possible address
combination, recording the
machine's address if it replies.
It is important that all machines
be powered on, else a machine
will not be recorded. Use this
function only if machines are
added or removed from the
network, if a display panel has lost its configuration, or if a software update is made on any machine (i.e. a
newer version number).