Figure 126: Edit Humidity Control Setup; Figure 127: Send Humidity Control Setup - Jamesway Sentry Manual

Display panel
Table of Contents

Advertisement

Here the operator can edit the
'Humidity Control Setup' for
all machines of a specific type.
The default variables shown
under the cursor can be used
by selecting "ENTER", or new
variables can be entered using
the "SELECT" key. The Auto
Damper can be either enabled
or disabled. The humidity pan
can be set to fill at any day
from day 1 to day 14. If a
value is entered outside the
specified range, an 'Entry
Error' message will appear.
Pressing "EXIT" will return to
the previous submenu without
making any changes to the 'Humidity Control' setup.
Once the desired Humidity
Control variables have been
entered, the operator has two
options: 'Abort' returns to the
previous screen without
altering the Humidity Control
setup, and 'Send Humidity
Setup' sends the new values to
all machines of a specific type
and activates the new
Humidity Control variables
immediately.
72 Sentry Control System

Figure 126: Edit Humidity Control Setup

Figure 127: Send Humidity Control Setup