NEC Business Solutions Ltd
DP Interdigit Time Selection
General Description
The DP Interdigit Time is the minimum pause time interval between Dial Pulse dialling. Use
this Memory Block to Select either Pattern A or Pattern B
New Zealand - DP for COI/D is not allowed.
Display
Data
No.
0 1 : D P
T I M E
Settings
LK 1
LK 2
Pattern A
Pattern B
LK 5
LK 6
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
KA
3 Press the corresponding CO/PBX line key to change the data option.
DP Dial
Data
Pattern A
Pattern B
N
4 Press
to write the data.
P
5 Press
to go back on-line.
N
Use this Memory Block when CO/PBX or Tie lines are assigned in Memory Block 3-91 Trunk (Installed, DP/DTMF)
Selection, to send Dial Pulse signalling.
1 - 30
Setting
Title
Data
I N T E R
B
D I S P L A Y
LK 3
LK 4
The shaded area indicates the default setting.
LK 7
LK 8
to access the Memory Block.
10 pps
20 pps
650 ms.
500 ms.
800 ms.
800 ms.
Minimum
Dial
Pause
Signal
Time
DP Interdigit Time Selection
Xen Master & Xen Axis
1-1-01
System Mode
1
Submode
1
Data No.
01
PC Programming
a
+BCM
Dial
Signal