NEC Xen Master Programming Manual page 401

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

Programming Manual
SLT Data Line Security Assignment
General Description
Use this Memory Block to specify Normal/Data position for Single Line Telephones (SLTs).
Display
Tel Port No.
(01~99)
Data
A0~C0
No.
0 1 / 9 0 : S L T
T I M E
Settings
LK 1
LK 2
SLT Normal
SLT Data
LK 5
LK 6
Programming Procedures
1 Go off-line.
2 Press LK4 +
IK
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change data option.
Use the following to change option:
R
select next Tel Port No.
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. When connecting SLT/voice mail, assign SLT Normal. When connecting Fax/Modem, assign SLT Data.
2. If Multiline Terminal is assigned for Data Line Security, Tone Override and Call Alert Notification tones are not heard
from the handset; however, the tone is still sent and heard from the speaker when off-hook.
3. Data Line Security denies a station from barging in, even if Barge-In is allowed in Class of Service.
4. If this Memory Block is set to SLT Data, the Voice Override tone is not heard when doing a Voice Over Split.
5. Telephone ports A0~C0 are ports 100~120.
SLT Data Line Security Assignment
Setting
Title
Data
N O R M A L
D I S P L A Y
LK 3
LK 4
The shaded area indicates the default setting.
LK 7
LK 8
May 2003
4-90
System Mode
4
Submode
Data No.
90
PC Programming
a
+BTT
1 - 383

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xen axis

Table of Contents