Programming Manual
External Speaker Connection
Selection
General Description
Use this Memory Block to specify whether or not external speakers are connected to the
system.
Display
Data
No.
0 2 : E S P
T I M E
Settings
LK 1
LK 2
ESP A
ESP B
LK 5
LK 6
Programming Procedures
1 Go off-line.
KB
2 Press LK1 + LK7 +
3 Press the CO/PBX line key corresponding to each ESP Zone. The LED changes to indicate the data each time the CPO/PBX line
key is pressed.
CO/PBX
Line LED
Data
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-7-03
External Paging Alert Zone Selection
N
Only three external speaker zones can be connected to the system.
External Speaker Connection Selection
Title
C O N N
D I S P L A Y
LK 3
LK 4
ESP C
The shaded area indicates the default setting.
LK 7
LK 8
to access the Memory Block.
Off
On
No
Yes
There is no default setting.
Memory Block Name
May 2003
1-7-02
System Mode
1
Submode
7
Data No.
02
PC Programming
a
+BP
1 - 183