NEC Xen Master Programming Manual page 362

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

NEC Business Solutions Ltd
SLT Hookflash Assignment
General Description
Use this memory block to specify the Single Line Telephone (SLT) hooking operation to
either Hold or disconnect the trunk.
Display
Tel Port
No.
Data
(01~99)
No.
A0~C0
0 1 / 2 4 : S L T
T I M E
Settings
LK 1
LK 2
Hold
Disc
LK 5
LK 6
Programming Procedures
1 Go off-line.
BD
2 Press LK4 +
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change data option.
Note:
Use the following to change option:
R
to go to next Tel Port No.
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-3-02
SLT Hookflash Signal Selection
4-23
Prime Line/Hot Line Assignment
N
1. This Memory Block affects only Single Line Telephone stations assigned Prime Line in Memory Block 4-23 Prime
Line/Hot Line Assignment.
2. When Prime Line is assigned to an Single Line Telephone, hookflash drops the CO and issues intercom (ICM) dial
tone if this Memory Block is set to disconnect.
3. After an SLT begins to dial out 9 +, hookflash follows Memory Block 1-3-02 SLT Hookflash Signal Selection
selection.
4. Telephone ports A0~C0 are ports 100~120.
1 - 344
Setting
Title
Data
H K H O L D
D I S P L A Y
LK 3
LK 4
The shaded area indicates the default setting.
LK 7
LK 8
Memory Block Name
Xen Master & Xen Axis
4-24
System Mode
4
Submode
Data No.
24
PC Programming
a
+BTI
SLT Hookflash Assignment