First Digit PBR Release Timer
Selection
General Description
Use this Memory Block to specify how long a Push Button Receiver (PBR) receiver circuit is
connected when a dual-tone multifrequency (DTMF) Single Line Telephone user goes off-
hook. After the timer expires the PBR is disconnected. If the Single Line Telephone user
dials a digit before the timer expires, a PBR interdigit timer starts.
Display
Data
No.
0 3 : P B R
T I M E
Settings
LK 1
LK 2
10 sec.
20 sec.
LK 5
LK 6
50 sec.
60 sec.
Programming Procedures
1 Go off-line.
KC
2 Press LK1 + LK1 +
3 Press the corresponding CO/PBX line key to change data option.
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-8-10
PBR Interdigit Release Timer Selection
4-93
DTMF/DP SLT Type Selection
First Digit PBR Release Timer Selection
Setting
Title
Data
R L S
1 0 s
D I S P L A Y
LK 3
LK 4
30 sec.
40 sec.
The shaded area indicates the default setting.
LK 7
LK 8
to access the Memory Block.
Memory Block Name
May 2003
1-3-03
System Mode
1
Submode
3
Data No.
03