MIF (ACD) Assignment
General Description
Use this Memory Block to enable the Automatic Call Distribution (ACD) function of the
MIFA-U13 ETU.
Display
Data
No.
Title
0 0 : A C D
T I M E
Programming Procedures
1 Go off-line.
2 Press LK7 + LK3 to access the Memory Block.
3 Use the dial pad to enter data.
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Setting Data 00, 01, 02
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. The ACD feature requires a KMA(1.0)U unit to be installed on the MIFA-U13 ETU.
2. ACD is not supported on the Xen Axis system.
MIF (ACD) Assignment
Setting
Data
M I F = 0 0
D I S P L A Y
System Mode
7
MIF
3
Data No.
00
PC Programming
a
+BS
Default Values
No Assignment (00)