NEC Xen Master Programming Manual page 428

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

NEC Business Solutions Ltd
MIF (LCR) Assignment
General Description
Use this Memory Block to enable the Least Cost Routing (LCR) function of the MIFM-U13
ETU.
Display
Data
Title
No.
0 1 : L C R
T I M E
Programming Procedures
1 Go off-line.
KA
2 Press LK7 + LK3 +
3 Use the dial pad to enter data.
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
~
K
I
to enter numeric data
Setting Data 00, 01, 02
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. The LCR feature requires a KMM(1.0)U unit to be installed on the MIFM-U13 ETU.
2. SMDR feature is enabled automatically when LCR is set to 01.
1 - 410
Setting
Data
M I F = 0 0
D I S P L A Y
to access the Memory Block.
Xen Master & Xen Axis
System Mode
7
MIF
3
Data No.
01
PC Programming
a
+BS
Default Values
No Assignment (00)
MIF (LCR) Assignment
7-3-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xen axis

Table of Contents