NEC Xen Master Programming Manual page 251

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

Programming Manual
ID Restriction Class Assignment
(Night Mode)
General Description
Use this Memory Block to specify the NIGHT mode code restriction classes for each
ID number.
Display
ID Buffer No.
Data
(01~96)
No.
0 1 / 0 4 : C L S
T I M E
Programming Procedures
1 Go off-line.
KD
2 Press LK1 + LK9 +
3 Use the dial pad to enter the data.
Setting Data:
Code Restriction Class 00 ~ 15
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
I
~
to enter numeric data
R
to access the next ID buffer number
Q
+1, 2, 3 = A, B, or C for Port Number
ID Buffer Number:
01~99 = 01~99
A0~A9 = 100~109
B0~B9 = 110~119
C0
= 120
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-1-19
Line Selection for Automatic Outgoing Calls
1-1-46
DID Digit Length Selection
1-1-47
DID Digit Conversion Assignment
1-1-48
DID Forward Station Number for Undefined Digit
* * 1-5-23 * *
T.B.A.
1-9-00
DISA/ID Code Assignment
1-9-02
DISA/ID Password Effect/Invalid Selection
1-9-03
ID Restriction Class Assignment (Day Mode)
ID Restriction Class Assignment (Night Mode)
Setting
Title
Data
N T = 0 0
D I S P L A Y
to access the Memory Block.
Default Values
Memory Block Name
System Mode
1
Submode
9
Data No.
04
PC Programming
a
+BO
ID Buffer No. 01~120 = Code
Restriction Class No.00
May 2003
1-9-04
1 - 233

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xen axis

Table of Contents