NEC Xen Master Programming Manual page 155

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

Programming Manual
Bounce Protect Time Selection
General Description
Use this Memory Block to specify the time before a valid hookflash is detected from a
Single Line Telephone or Voice Mail system.
Display
Data
No.
Title
0 1 : B N C E
T I M E
Settings
(Page 1)
LK 1
LK 2
0 ms.
100 ms.
LK 5
LK 6
400 ms.
500 ms.
(Page 2)
LK 1
LK 2
800 ms.
900 ms.
LK 5
LK 6
1200 ms.
1300 ms.
Programming Procedures
1 Go off-line.
2 Press LK1 + LK3 +
KA
3 Press the corresponding CO/PBX line key to change the data option.
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-3-05
Hookflash Start Time Selection
N
Bounce Protect Time should be equal to Hookflash Start Time in Memory Block 1-3-05 Hookflash Start Time Selection.
Bounce Protect Time Selection
Setting
Page
Data
No.
3 0 0 m s
| 1
D I S P L A Y
LK 3
LK 4
200 ms.
300 ms.
LK 7
LK 8
600 ms.
700 ms.
The shaded area indicates the default setting.
LK 3
LK 4
1000 ms.
1100 ms.
LK 7
LK 8
1400 ms.
1500 ms.
to access the Memory Block.
Memory Block Name
May 2003
1-3-01
System Mode
1
Submode
3
Data No.
01
PC Programming
a
+BTI
1 - 137