NEC Xen Master Programming Manual page 423

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

Programming Manual
Related Programming
M.B. Number
1-1-46
Access Code (1-Digit) Assignment
3-03
Trunk-to-Trunk Group Assignment
7-3-00
MIF (ACD) Assignment
7-3-01
MIF (LCR) Assignment
7-3-02
MIF (SMDR) Assignment
7-3-03
MIF (UCD) Assignment
7-3-04
MIF (Caller ID) Assignment
N
1. ETU Interface cards are assigned automatically during initial power up.
2. ESI(8)-U13 ETU with ports 01 and 02 cannot be changed.
3. If system port capacity is exceeded when an ETU is installed, ERROR is displayed on the LCD, and pressing the
Transfer key will not accept the setting.
4. The PRT(1)-U13 ETU must be installed in Slot S4 of the first KSU or Slot S1 of the second KSU of a Xen Master
system, or Slot S4 of the Xen Axis system.
5. The PRT(1)-U13 ETU must be assigned in both the supper and lower portions of each slot. When the PRT(1)-U13
ETU is first assigned in a slot, the lower slot is automatically assigned with the first number of the first block of four
PRI ports. Press
channels. Press
required to accommodate the number of channels provided by the PRI service. Each slot supports 8 channels. Next
program Memory Block 1-13-00.
PRI(10) = occupies 2 slots in total
PRI(20) = occupies 3 slots in total
PRI(30) = occupies 4 slots in total
6. When changing an interface slot assignment to a different ETU, use the following procedure:
a. Remove the ETU installed in the slot.
b. Program the slot for the new ETU in this Memory Block.
c. Install the new ETU.
7. The COID(4)-U13 (NZ - U19), COID(8)-U13 (NZ - U19) and BRT(4)-U13 ETUs must be installed in Slots S1~S4 of
the first or second KSU of a Xen Master system, or Slots S3~S4 of a Xen Axis system.
8. When a PRT or BRT ETU is installed, a CLK G( )-U13 Unit must be fitted to the CPU B( )-U13/MBD-U13 KSU.
9. The VMS(2)-U13 ETU must be assigned as a VMS(4)-U13 ETU in this Memory Block.
10. The B64-U13 KSU also has one ISA application slot.
11. The B48-U13 KSU of the Xen Axis system has five universal slots and one ISA application slot.
12. The MIFM-U13 or MIFA-U13 ETU must be installed in the ISA slot or Slots S1and S2 of the B64-U13 KSU (Xen
Master), or the ISA slot S2 of the B48-U13 KSU (Xen Axis).
13. The MIFM-U13 ETU has an optional built-in modem that works only when the MIFM-U13 ETU is installed in slots S1
or Sw.
14. The MIFA-U13 ETU (with KMA( )UA installed) has an ACD-MIS output that works only when the MIFA-U13 ETU is
installed in the ISA slot (not an interface slot).
Note: The ACD is not supported by the Xen Axis system.
15. If both ACD-MIS and Remote PC Programming via the MIF-Modem are required, install the MIFA-U13 ETU in the ISA
slot and the MIFM-U13 ETU in interface slots S1 or S2.
Note: The ACD is not supported by the Xen Axis system.
16. Any interface circuit ETU occupies eight ports regardless of the number of circuits contained on that ETU.
17. Refer to the Xen Hardware Manual or Xen Features and Specifications Manual for more information.
18. CNF(8)-13 must be assigned using SLI (8) Setting Data in MB 7-1. System software recognises and assigns CNF(8)
as SLI(8) at start-up.
Each Conference Card added to the system requires to be assigned as an SLI Card.
Card Interface Slot Assignment
Q
N
and enter the upper slot number, which is the first number of the next block of four PRI
and repeat this process for each slot after the PRT(1)-U13 ETU, for as many slots as are
Memory Block Name
May 2003
1 - 405

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xen axis

Table of Contents