1 - 440
6.6
Code Restriction Algorithm
The following chart identifies how the system checks for and processes Code
Restriction assignments.
.
User Accesses a
CO/PBX Line
Code
Restriction Class
Class 00
(Day, Night)
M. B. 4-7
and 4-8
Is line
Assigned as
PBX?
M. B. 3-91
Allow User
to Dial 1
1st Digit
0, 2~9
Search Only 8-Digit Matching Table
From Table 00~15 After Each Digit For
the First 8 Digits
Search Only 8-Digit Matching Tables
Assigned To Class Assignment
M. B. 1-1-61
Search Only 8-Digit Matching Tables
Assigned To Normal Dial
M. B. 1-1-66
Search Only 8-Digit Matching Tables
Assigned for Trunk Group Being Used
M. B. 5 - TRF-02
Class 15
Class 01 ~ 14
Yes
No
Yes
Digit
1
1
Xen Master & Xen Axis
Disconnect
Issue Error
User
Dials PBX
Access Code
No
M. B. 1-1-26
or M. B. 1-1-25
1~9
No Match
Found
OCC Table
Assignment
M. B. 1-1-67
Match Found
2
Allow User
Free
Dialling
Allow User
to Dial 1
Digit
2nd Digit
0
Allow User
to Dial up to
6 More
Digits
Search OCC
Tables From
Tables 01~16
Allow User
Free
Dialling

Advertisement