NEC Xen Master Programming Manual page 194

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

NEC Business Solutions Ltd
DSS Call Voice/Tone Signal
Selection
General Description
Use this Memory Block to specify which is to be used first, Voice or Tone signaling, when
calling an extension from an Attendant Add-On Console.
Display
Data
No.
0 3 : V O I C E
T I M E
Settings
LK 1
LK 2
Tone
Voice
LK 5
LK 6
Programming Procedures
1 Go off-line.
2 Press LK1 + LK6
.
J
3 Use
to move cursor to the second Data No. position and press
4 Press the corresponding CO/PBX line key to change the data option.
N
5 Press
to write the data.
P
6 Press
to go back on-line.
Related Programming
M.B. Number
1-6-01
Attendant Add-On Console to Telephone Port Assignment
N
1. Voice/tone signaling can also be switched by dialling 1 from a station.
2. If tone signaling is programmed in this Memory Block, the called party cannot answer handsfree unless the Direct
Station Select (DSS) station switches it to Voice by dialling 1.
1 - 176
Setting
Data
C A L L
D I S P L A Y
LK 3
LK 4
The shaded area indicates the default setting.
LK 7
LK 8
C
to access the Memory Block.
Memory Block Name
Xen Master & Xen Axis
System Mode
1
Submode
6
Data No.
03
PC Programming
a
+BTD
DSS Call Voice/Tone Signal Selection
1-6-03