Station Number Assignment
General Description
Use this memory block to assign a station number to each telephone.
Display
Tel Port
No.
Data
(01~99)
No.
A0~C0
0 1 / 1 0 : S T A
T I M E
Programming Procedures
1 Go off-line.
2 Press LK4 +
AK
to access the Memory Block.
3 Use dial pad to enter Setting Data for 2- (00
4-digit (0000
9999) station number.
~
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
I
~
to enter numeric data
R
to move to the next Tel No
4 After entering all data, press
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-1-46
Access Code (1-Digit) Assignment
1-1-47
Access Code (2-Digit) Assignment
1-2-03
2-, 3-, or 4-Digit Station Number Selection
N
1. Station Number Assignment is per station. A station number cannot be assigned to more than one telephone. A
telephone cannot have more than one station number.
2. When changing Station Numbers to a different numbering plan perform the following steps in order.
a. Select Station Numbers using Memory Block 1-2-03 2-, 3-, or 4-Digit Station Number Selection.
b. Program applicable Access Code in Memory Block 1-1-46 Access Code (1-Digit) Assignment or 1-1-47
Access Code (2-Digit) Assignment.
c. Program all Station Numbers using this Memory Block.
3. Telephone ports A0~C0 are ports 100~120.
1 - 332
Setting
Data
Title
(00~9999)
=
1 0 0
D I S P L A Y
99) , 3- (000
~
N
to write the data.
999), or
~
Memory Block Name
Xen Master & Xen Axis
4-10
System Mode
4
Submode
Data No.
10
PC Programming
a
+BS
Default Values
Valid Station Numbers are 100
Station Number Assignment
399.
~