ECR Relay to Tenant Assignment
General Description
Use this Memory Block to specify Tenant Assignment for External Tone Ring/Night Chime
function.
Display
Tenant No.
Data
(00~47)
No.
0 0 / 0 8 : R L Y
T I M E
Settings
LK 1
LK 2
External
External
Tone Relay
Tone
1
Relay 2
LK 5
LK 6
Night Chime
Programming Procedures
1 Go off-line.
KH
2 Press LK2 +
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Note:
Use the following to enter data:
J
to moves the cursor left
L
to moves the cursor right
R
to go to the next Tenant No.
N
4 Press the
to write the data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-7-07
External Ring Relay Cycle Selection
N
1. By assigning Night Chime to a Tenant, incoming calls to the Tenant Group in Night Mode can be answered using the
Night Call Pickup Access Code.
2. The relays are fixed (non programmable).
3. Night Chime must be assigned for Night Call Pickup to work. A relay may be assigned even if no ECR-U13 ETU is
installed in the system.
ECR Relay to Tenant Assignment
Title
T E N A N T
D I S P L A Y
LK 3
LK 4
There is no default value.
External
External
Tone
Tone
Relay3
Relay 4
LK 7
LK 8
Default Values
All Tenants No Assignment
Memory Block Name
May 2003
2-08
System Mode
2
Submode
Data No.
08
PC Programming
a
+BN
1 - 261