NEC Xen Master Programming Manual page 179

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

Programming Manual
Automated Attendant Message
Access Code (2-Digit) Assignment
General Description
Use this Memory Block to enter a 2-digit code to route an incoming call from the Automated
Attendant.
Display
Data
No.
Title
1 5 : A A
T I M E
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
AE
3 Use the dial pad to enter data.
Note:
The following are used when entering data:
K~H
to enter Automated Attendant message number
KK~II
4 Enter Setting Data. Press
5 After all data is entered, press
P
6 Press
to go back on-line.
Related Programming
M.B. Number
Refer to Chapter 2 Guide to Feature Programming
Automated Attendant Message Access Code (2-Digit) Assignment
A.A. Msg.
No.
Dial
Setting
1~8
No.
Data
A C 1 = 0 0 = 0 3 0
D I S P L A Y
to access the Memory Block.
to enter dial number
N
to write the data and to advance the Dial Number.
N
to write the data.
Default Values
Dial No.
Funct. Code
00 ~ 50
51
52
53
54
55 ~ 87
88
89
90~99
Memory Block Name
System Mode
1
Submode
4
Data No.
15
PC Programming
a
+ AU
Contents
030
Specified Station Cal (0)
Bypass Automated
011
Attendant
015
Paging Zone A Call
016
Paging Zone B Call
017
Paging Zone C Call
000
Not Used
020
DSS 1 Call
021
DSS 2 Call
000
Not Used
May 2003
1-4-15