Communications
The Communications pulldown menu allows access to system data items relating
to direct and remote connections to the Xen system.

Figure 3-10 Communications Menu

Connect
This option allows the technician to connect to the Xen system.
Connection can be Direct or Remote. Direct connection is when the MAT PC is
directly connected to the Xen system. With Remote connection, the MAT PC uses
a modem to dial into another external remote modem that is connected to the Xen
system. If the MIFM-U13 KTU is equipped with a socket modem (modem kit part
no. 750620), then the external remote modem is not needed. For Direct connection
to the KTS, connect the serial cable included with the MAT from a free serial port on
the MAT PC to the COM 1 port on the KTS. Select Communications, Connect.
Select the Setup button to choose PC COM port. Choose Direct Connection and
click the Connect button. For Remote connection to the KTS, choose Modem
Connection and select the Dial button. For this type of connection, the PC must
have an MNP Class 4 modem. This type of connection allows the user to program a
KTS located at a remote location.
In either case, after a successful connection is established with the KTS, you are
ready to upload and download data to and from the KTS.
Disconnect
This option allows the technician to disconnect from the Xen system.
Upload
This option allows the technician to upload programming changes and
configurations to the KTS.
Download
This option allows the technician to download the current Xen configuration.