NEC Xen Master Programming Manual page 165

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

Programming Manual
Tandem Transfer Automatic
Disconnect Timer Selection
General Description
Use this Memory Block to specify maximum time before the system automatically
disconnects a Trunk-to-Trunk connection.
Display
Data
No.
0 0 : A U T O
T I M E
Settings
LK 1
LK 2
30 min.
1 hr.
LK 5
LK 6
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
KK
3 Press the corresponding CO/PBX line key to change the data
option or enter the time required in minutes
N
4 Press
to write the data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
Refer to Chapter 2 Guide to Feature Programming
N
This block is used for Direct Inward System Access (DISA), Trunk-to-Trunk Transfer, Call Forward - Off Premise, and Tie
line tandem features.
Tandem Transfer Automatic Disconnect Timer Selection
Setting
Title
Data
D I S
0 6 0
D I S P L A Y
LK 3
LK 4
2 hr.
3 hr.
The shaded area indicates the default setting.
LK 7
LK 8
to access the Memory Block.
Default Values
060 min
Setting Data
000~999 (Software Version 2.xx or later)
Memory Block Name
May 2003
1-4-00
System Mode
1
Submode
4
Data No.
00
PC Programming
a
+AT
1 - 147

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xen axis