Rockwell Automation MagneMotion QuickStick HT User Manual page 305

Table of Contents

Advertisement

2.
Reconnect all cables to the motor drive (refer to the labels previously placed on the
cables).
3.
Restore power to the section of the QSHT transport system where the motor drive was
replaced.
4.
If the drive being replaced is a QSHT 5700 inverter:
A.
Update the MICS file (see
MAC address and static IPv4 address of the inverter.
B.
Upload the MICS file to all node controllers (see the Node Controller Interface
User Manual, MMI-UM001).
C.
Cycle logic power to the motors to force the motors to request their network
provisioning.
5.
Program the masters and slaves on the new motor drive with the current Motor ERF
Image files (see
6.
Resume motion on the section of the QSHT transport system where the motor drive
was replaced.
QuickStick HT User Manual
Ethernet Motor MICS File on page
Programming Motors on page
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
89) with the new
306).
Maintenance
Repair
305

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MagneMotion QuickStick HT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents