Table 4-38: QSHT 5700 Inverter Safety Connector Pinout
1
8
1
SB+ this is used to enable motion when safety is not
required by jumpering to the SS_IN pins
2
SS_IN_CH0 (Safe-stop input channel 1) – Inverter A
3
SS_COM (Safe-stop input common)
4
SS_IN_CH1 (Safe-stop input channel 2) – Inverter A
5
SB- this is used to enable motion when safety is not
required by jumpering to the SS_COM pins
6
SS_IN_CH0 (Safe-stop input channel 1) – Inverter B
7
SS_COM (Safe-stop input common)
8
SS_IN_CH1 (Safe-stop input channel 2) – Inverter B
9
Not Connected
10
SS_IN_CH0 (Safe-stop input channel 1) – Inverter A
11
SS_COM (Safe-stop input common)
12
SS_IN_CH1 (Safe-stop input channel 2) – Inverter A
13
SB- this is used to enable motion when safety is not
required by jumpering to the SS_COM pins
14
SS_IN_CH0 (Safe-stop input channel 1) – Inverter B
15
SS_COM (Safe-stop input common)
16
SS_IN_CH1 (Safe-stop input channel 2) – Inverter B
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
9
SB+/NC
S1A
SCA
S2A
SB-
S1B
SCB
S2B