Transport System Installation
The QuickStick HT transport system must be properly located within the facility so that other
equipment can interface to it as required. The location must also make sure that there is ade-
quate space for service access and for proper operation. Make sure that installation of the
QuickStick HT components provides access to items required for service after installation,
such as connection panels. Once properly located, the QSHT transport system must be leveled
and secured to the floor or other rigid mounting points to help prevent any movement.
Installing Hardware
To install the motors on user-supplied supports, make sure that the supports are properly pre-
pared to receive the motors (see
(see
Mounting the Motors on page
the custom supports.
NOTE: Any bolts with plastic caps have been pre-tightened at the factory to the appropriate
torque specification and do not need to be tightened during installation.
When performing any of the following procedures, adhere to and follow all safety
warnings and instructions.
Required Tools and Materials
•
Metric Hex wrench set.
•
Torque wrench (0.9–4.8 N•m [8–42 in•lb] range) with metric and Torx bits.
•
Soft jaw pliers.
•
Screwdriver, Small flat blade.
•
Screwdriver, Phillips.
•
12" Machinist Square.
•
Laser level, rotary.
•
Digital Multimeter.
QuickStick HT User Manual
Mechanical Specifications on page
181) and make any adjustments necessary to account for
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Installation
Transport System Installation
124). Install the motors
179