Ac Power - Oracle Fabric Interconnect Series User Manual

Table of Contents

Advertisement

1 stop bit
The Serial 2 port is used for debug purposes only.
Note -

AC Power

Your system is shipped with power cords that are suitable for your location. However, Oracle
recommends that you inspect the cords to ensure that they are of the correct type.
See the appropriate section:
"Connect Power to the Fabric Interconnect F1-15" on page 89
"Connect Power for the Fabric Interconnect F1-4" on page 90
Connect Power to the Fabric Interconnect F1-15
The Fabric Interconnect F1-15's power supplies are located on the front of the chassis, and the
power plugs are on the rear of the chassis as shown in
Power Supplies for Connecting to AC Facility Power," on page
Verify that your AC power source, as well as any equipment installed between the
Caution -
power source and the Fabric Interconnect (such as surge suppressors, plug bars, and so on)
meet these requirements: – 100 - 127 / 200 - 240 V AC – 12 - 7.68 A – 47 - 63 Hz – 1220 W
(maximum)
To connect Oracle Fabric Interconnect F1-15 to facility power, follow this procedure:
1.
Connect the dual power supplies to an AC power source. See
Interconnect F1-15 Power Supplies for Connecting to AC Facility Power," on
page
90.
Connect Power to the Fabric Interconnect F1-15
Figure 57, "Fabric Interconnect F1-15
90.
Figure 57, "Fabric
Installing the Fabric Interconnect
89