Fault code
J1939 SPN
J1939 FMI
Engine coolant temperature - Data valid but
2963
above normal operational range - Least severe
110
level. Engine coolant temperature is above the
15
engine protection warning limit.
Intake manifold 1 temperature - Data valid but
2964
above normal operational range - Least severe
105
level. Intake manifold air temperature signal
15
indicates intake manifold air temperature is
above engine protection warning limit.
2973
Intake manifold 1 pressure - Data erratic,
102
intermittent, or incorrect. The intake manifold
2
pressure sensor is reading an erratic value.
Aftertreatment diesel exhaust fluid dosing unit
2976
temperature - Data erratic, intermittent, or
3361
incorrect. An internal error has been detected in
2
the aftertreatment diesel exhaust fluid dosing
unit.
Aftertreatment diesel particulate filter outlet
3133
pressure sensor circuit - Voltage above normal,
3610
or shorted to high source. High signal voltage
3
detected at the aftertreatment diesel particulate
filter outlet pressure sensor circuit.
Aftertreatment diesel particulate filter outlet
3134
pressure sensor circuit - Voltage below normal,
3610
or shorted to low source. Low signal voltage
4
detected at the aftertreatment diesel particulate
filter outlet pressure sensor circuit.
Aftertreatment diesel particulate filter outlet
3135
pressure - Data erratic, intermittent or incorrect.
3610
The aftertreatment diesel particulate filter outlet
2
pressure sensor is reading an erratic value at
initial key ON or during engine operation.
Aftertreatment SCR outlet temperature sensor
3146
circuit - Voltage above normal or shorted to high
4363
source. High signal voltage detected at the
3
SCR outlet temperature sensor circuit.
Aftertreatment SCR outlet temperature sensor
3147
circuit - Voltage below normal or shorted to low
4363
source. Low signal voltage detected at the
4
SCR outlet temperature sensor circuit.
Aftertreatment SCR outlet temperature sensor -
3148
Data erratic, intermittent, or incorrect. The SCR
4363
outlet temperature sensor is not changing with
2
engine operating conditions.
3151
Aftertreatment SCR catalyst system missing -
4794
Condition exists. The aftertreatment SCR
31
catalyst in the exhaust system is not present.
※ Some fault codes are not applied to this machine.
Reason
3-40
Effect (only when fault code is active)
Progressive power and/or speed derate
increasing in severity from time of alert. If the
Engine protection shutdown feature is enabled,
the engine will shut down 30 seconds after the
red STOP lamps starts flashing.
Progressive power and/or speed derate
increasing in severity from time of alert. If the
Engine protection shutdown feature is enabled,
the engine will shut down 30 seconds after the
red STOP lamps starts flashing.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.