Hyundai HL955 Manual page 83

Table of Contents

Advertisement

Fault code
J1939 SPN
J1939 FMI
196
Coolant level sensor 1 circuit - Voltage below
111
normal, or shorted to low source. Low signal
4
voltage detected at engine coolant level circuit.
197
Coolant level - Data valid but below normal
111
operational range - Moderately severe level.
18
Low coolant level has been detected.
Barometric pressure sensor circuit - Voltage
221
above normal, or shorted to high source. High
108
signal voltage detected at barometric pressure
3
circuit.
Barometric pressure sensor circuit - Voltage
222
below normal, or shorted to low source. Low
108
signal voltage detected at barometric pressure
4
circuit.
227
Sensor supply 2 circuit - Voltage above normal,
3510
or shor ted to high source. High voltage
3
detected at sensor supply number 2 circuit.
Engine crankshaft speed/position - Data valid
234
but above normal operational range - Most
190
severe level. Engine speed signal indicates
0
engine speed above engine protection limit.
Sensor supply 3 circuit - Voltage below normal,
238
or shorted to low source. Low voltage detected
3511
on the +5 volt sensor supply circuit to the
4
engine speed sensor.
Sensor supply 3 circuit - Voltage above normal
239
or shor ted to high source. High voltage
3511
detected on the 5 volt sensor supply circuit to
3
the engine speed sensor.
Wheel-based vehicle speed - Data erratic,
241
intermittent, or incorrect. The ECM lost the
84
vehicle speed signal or is reading an erratic
2
value.
Fan control circuit - Voltage below normal, or
245
shorted to low source. Low signal voltage
647
detected at the fan control circuit when
4
commanded on.
Ambient air temperature sensor 1 circuit -
249
Voltage above normal or shorted to high
171
source. High signal voltage detected at ambient
3
air temperature circuit.
Ambient air temperature sensor 1 circuit -
256
Voltage below normal or shorted to low source.
171
L ow vo l t a g e d e t e c t e d a t a m b i e n t a i r
4
temperature circuit.
Fuel pump pressurizing assembly 1 circuit -
271
Voltage below normal, or shorted to low source.
1347
Low signal voltage detected at the fuel pump
4
actuator circuit.
※ Some fault codes are not applied to this machine.
Reason
3-27
Effect (only when fault code is active)
None on performance.
Engine power derate.
Engine power derate.
Engine power derate.
Engine power derate.
Engine power derate.
Engine may run rough, may stop running, may
not start, or may be difficult to start.
Engine may run rough, may stop running, may
not start, or may be difficult to start.
Engine speed limited to ,maximum engine
speed without VSS parameter value. Cruise
control, gear-down protection, and road speed
governor will not work.
The fan may stay on continuously or not run at
all.
Possible reduced engine performance.
Possible reduced engine performance.
Engine power derate.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl955tm

Table of Contents