Group 6 Troubleshooting - Hyundai HL955 Manual

Table of Contents

Advertisement

GROUP 6 TROUBLESHOOTING

GROUP 6 TROUBLESHOOTING
1. 1. WHEN STARTING SWITCH IS TURNED ON, CLUSTER
WHEN STARTING SWITCH IS TURNED ON, CLUSTER AND MONITOR
LIGHT UP
LIGHT UP
·Before carrying out below procedure, check all the related connectors are properly inserted and the
fuse No.17 is not blown out and ON/OFF of bulb.
·After checking, connect the disconnected connectors again immediately unless otherwise
specified.
YES
Check voltage
between CN-56
(1), CN-57(1) and
chassis
NO
MONITOR
1
CN-57
CLUSTER
1
CN-56
Check voltage
YES
20 ~ 30 V
NO
0 V
AND MONITOR LAMP DOES NOT
Defective cluster
Defective monitor
Disconnection in
wiring harness or
poor contact
between CN-56
(1), CN-57 (1)
and fuse No. 17
7-97
LAMP DOES NOT
Cause
Remedy
Replace
Replace
Repair or
replace
(after clean)
FUSE [CN-37]
No.17
760F7EL24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl955tm

Table of Contents