⑥
Work load mode
Work load mode
760F3CD33A
·
Weighing system : Set the workload measurements.
·
Weighing display : Set the display on main display screen.
·
Initialization : Workload initialization.
·
Error detection : Set error detection ON/OFF.
- OFF : Errors are not displayed.
- ON : ⓐ,ⓑ and ⓒ are displayed on main display screen.
ⓐ
The boom lift was performed too fast.
ⓑ
The bucket was not in the fully tilted back position while
bucket was in the weigh range.
ⓒ
The hydraulic temperature is low (below 40 ˚C).
·
Boom pressure calibration : See the page 3-26 for details.
※
Refer to page 7-62 for details.
Refer to page 7-62 for details.
※
Weighing system
Weighing system
-
The weight indication in bucket is
calculated by measuring boom position
and boom pressure.
ⓐ
The weight is '0.0 ton' when the boom is
placed at below -15˚.
ⓑ
The weight is indicated when the boom is
placed at the range (-5˚→15˚).
ⓒ
The weight is calculated when the boom is
placed at above -5˚ and boom is lowered
below -15˚ after dumping operation.
In order to recheck weight, go to the ⓑ after changing boom position (below -15˚).
-
Dump operation : It is checked by bucket cylinder's stroke change (below 250 mm).
※
The temperature for the hydraulic oil must be raised to at least 40 ˚C (104 ˚F) before opera-
tion.
760F3CD33B-1
15
0
-5
-15
7-42
a
c
b
760F3CD33CK
760F3CD126