4) 4)
ASSEMBLY
ASSEMBLY
(1)
(1)
Assemble gland assembly
Assemble gland assembly
Check for scratches or rough surfaces if
found smooth with an oil stone.
Coat the inner face of gland (3) with
hydraulic oil.
Coat dust wiper (4) with grease and fit
dust wiper (4) to the bottom of the hole of
dust wiper.
At this time, press a pad metal to the
metal ring of dust seal.
Fit snap ring (5) to the stop face.
Fit back up ring (7) and rod seal (6), and
buffer ring (8) to corresponding grooves,
in that order.
Coat each packing with hydraulic oil
before fitting it.
Insert the backup ring until onside of it is
inserted into groove.
Rod seal (6) has its own fitting direction.
Therefore, confirm it before fitting them.
Fitting rod seal (6) up side down may
damage its lip. Therefore check the
correct direction that is shown in figure.
3
Press here(Straight down)
4
Wrong
6
5-50
7577ASE34
Metal
75795SE24
Right
7577ASE42
Push bar
7577ASE43

Advertisement