Hyundai HL955 Manual page 104

Table of Contents

Advertisement

Fault code
J1939 SPN
J1939 FMI
Aftertreatment diesel exhaust fluid pressure
3575
sensor - Data valid but above normal operating
4334
range - Moderately severe level. The diesel
16
exhaust fluid dosing unit has detected a
blockage in the diesel exhaust fluid return flow.
Aftertreatment diesel exhaust fluid return valve -
3577
Voltage above normal or shorted to high
4376
source. High signal voltage detected at the
3
aftertreatment diesel exhaust fluid return valve.
Aftertreatment diesel exhaust fluid return valve -
3578
Voltage below normal, or shorted to low source.
4376
Low signal voltage detected at the diesel
4
exhaust fluid return valve.
Aftertreatment SCR catalyst conversion
3582
efficiency - Data valid but below normal
4364
operating range - Moderately severe level. NOx
18
conversion across the SCR catalyst is too low.
Aftertreatment outlet NOx sensor heater -
3583
Abnormal rate of change. The aftertreatment
5031
outlet NOx sensor heater is unable to maintain
10
its normal operating temperature.
Aftertreatment diesel exhaust fluid pressure
3596
sensor - Data erratic, intermittent, or incorrect.
4334
The diesel exhaust fluid pressure sensor has
2
reported a reading too high or low for the
operating conditions.
Aftertreatment Intake NOx sensor heater -
3649
Abnormal rate of change. The aftertreatment
5024
intake NOx sensor heater is unable to maintain
10
its normal operating temperature.
Aftertreatment outlet NOx sensor power supply
3681
- Data erratic, intermittent, or incorrect. The
3228
aftertreatment outlet NOx sensor indicates that
2
the power supply to the sensor is incorrect.
Aftertreatment Intake NOx sensor power supply
3682
- Data erratic, entermittent or encorrect. The
3218
aftertreatment intake NOx sensor indicates that
2
the power supply to the sensor is incorrect.
E
ngine control module calibration memory -
3697
Bad intelligent device or component.
630
Error internal to the ECM related to engine
12
software failures.
Aftertreatment SCR operator inducement -
3712
Data valid but above normal operational range -
5246
Most severe level. Critical SCR related fault
0
codes have been active for an extended period
of time and require immediate attention.
※ Some fault codes are not applied to this machine.
Reason
3-48
Effect (only when fault code is active)
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
None on performance.
Possible reduced engine performance.
None on performance.
None on performance.
None on performance.
Engine may not start or may be difficult to start.
Vehicle speed will be limited to 8 km [5 miles]
per hour.

Advertisement