Hyundai HL955 Manual page 94

Table of Contents

Advertisement

Fault code
J1939 SPN
J1939 FMI
EGR Valve control circuit - Current above
2353
normal or grounded circuit. A short circuit to
2791
ground has been detected in the EGR valve
6
motor circuit.
Fuel filter differential pressure - Data valid but
2372
above normal operational range - Moderately
95
severe level. Excessive fuel flow restriction to
16
the high pressure fuel pump has been detected.
Exhaust gas pressure sensor circuit - Voltage
2373
above normal or shorted to high source. High
1209
signal voltage detected at the exhaust gas
3
pressure circuit.
Exhaust gas pressure sensor circuit - Voltage
2374
below normal or shorted to low source. Low
1209
signal voltage detected at the exhaust gas
4
pressure circuit.
Exhaust gas recirculation temperature sensor
2375
circuit - Voltage above normal or shorted to high
412
source. High signal voltage detected at EGR
3
temperature circuit.
Exhaust gas recirculation temperature sensor
2376
circuit - Voltage below normal or shorted to low
412
source. Low signal voltage detected at EGR
4
temperature circuit.
2377
Fan control circuit - Voltage above normal, or
647
shorted to high source. Open circuit or high
3
voltage detected at the fan control circuit.
VGT Actuator driver circuit (motor) - Mechanical
2387
system not responding or out of adjustment.
641
The smar t VGT controller has detected
7
incorrect stop limits, or the VGT is unable to
move to the closed position.
2398
Ambient air temperature - Data erratic,
171
intermittent, or incorrect. The ambient air
2
temperature sensor is reading an erratic value.
2448
Coolant level - Data valid but below normal
111
operational range - Least severe level. Low
17
engine coolant level detected.
2449
Vgt actuator controller - Out of calibration.
641
The VGT actuator has been installed incorrectly.
13
Engine crankshaft speed/position - Data valid
2468
but above normal operating range - Moderately
102
severe level. The engine speed has exceeded a
3
critical limit.
2554
E x h a u s t g a s p r e s s u r e - D a t a e r ra t i c,
1209
intermittent or incorrect. The exhaust gas
2
pressure sensor is reading an erratic value.
※ Some fault codes are not applied to this machine.
Reason
3-38
Effect (only when fault code is active)
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
Possible reduced engine performance.
The fan can stay on continuously or not
all.
Possible reduced engine performance.
Possible reduced engine performance.
none on performance.
Possible reduced engine performance.
Engine will be shut down.
possible reduced engine performance.
not run at

Advertisement